SRF08 Ultra sonic range finder
Technical Specification
Communication with the SRF08 ultrasonic rangefinder is via the I2C bus. This is available on popular controllers such as the OOPic and Stamp BS2p, as well as a wide variety of micro-controllers. To the programmer the SRF08 behaves in the same way as the ubiquitous 24xx series eeprom's, except that the I2C address is different. The default shipped address of the SRF08 is 0xE0. It can be changed by the user to any of 16 addresses E0, E2, E4, E6, E8, EA, EC, EE, F0, F2, F4, F6, F8, FA, FC or FE, therefore up to 16 sonar's can be used. In addition to the above addresses, all sonar's on the I2C bus will respond to address 0 - the General Broadcast address. This means that writing a ranging command to I2C address 0 (0x00) will start all sonar's ranging at the same time. This should be useful in ANN Mode (See below). The results must be read individually from each sonar's real address. We have examples of using the SRF08 module with a wide range of popular controllers.
Connections
The "Do Not Connect" pin should be left
unconnected. It is actually the CPU MCLR line and is used once only in our
workshop to program the PIC16F872 on-board after assembly, and has an internal
pull-up resistor. The SCL and SDA lines should each have a pull-up resistor to
+5v somewhere on the I2C bus. You only need one pair of resistors, not a pair
for every module. They are normally located with the bus master rather than the
slaves. The SRF08 is always a slave - never a bus master. If you need them, I
recommend 1.8k resistors. Some modules such as the OOPic already have pull-up
resistors and you do not need to add any more.
Registers
The SRF08 appears as a set of 36
registers.
Location |
Read |
Write |
0 |
Software Revision |
Command Register |
1 |
Light Sensor |
Max Gain Register (default 31) |
2 |
1st Echo High Byte |
Range Register (default 255) |
3 |
1st Echo Low Byte |
N/A |
~~~~ |
~~~~ |
~~~~ |
34 |
17th Echo High Byte |
N/A |
35 |
17th Echo Low Byte |
N/A |
Only locations 0, 1 and 2 can be written to. Location 0 is the command register and is used to start a ranging session. It cannot be read. Reading from location 0 returns the SRF08 software revision. By default, the ranging lasts for 65mS, but can be changed by writing to the range register at location 2. If you do so, then you will likely need to change the analogue gain by writing to location 1. See the Changing Range and Analogue Gain sections below.
Location 1 is the onboard light sensor. This data is updated every time a new ranging command has completed and can be read when range data is read. The next two locations, 2 and 3, are the 16bit unsigned result from the latest ranging - high byte first. The meaning of this value depends on the command used, and is either the range in inches, or the range in cm or the flight time in uS. A value of zero indicates that no objects were detected. There are up to a further 16 results indicating echo's from more distant objects.
Commands
The are three commands to initiate a ranging
(80 to 82), to return the result in inches, centimeters or microseconds. There
is also an ANN mode (Artificial Neural Network) mode which is described later
and a set of commands to change the I2C address.
Command | Action | |
Decimal | Hex | |
80 | 0x50 | Ranging Mode - Result in inches |
81 | 0x51 | Ranging Mode - Result in centimeters |
82 | 0x52 | Ranging Mode - Result in micro-seconds |
83 | 0x53 | ANN Mode - Result in inches |
84 | 0x54 | ANN Mode - Result in centimeters |
85 | 0x55 | ANN Mode - Result in micro-seconds |
160 | 0xA0 | 1st in sequence to change I2C address |
165 | 0xA5 | 3rd in sequence to change I2C address |
170 | 0xAA | 2nd in sequence to change I2C address |
Ranging Mode
To initiate a ranging, write one of the
above commands to the command register and wait the required amount of time for
completion and read as many results as you wish. The echo buffer is cleared at
the start of each ranging. The first echo range is placed in locations 2,3. the
second in 4,5, etc. If a location (high and low bytes) is 0, then there will be
no further reading in the rest of the registers. The default and recommended
time for completion of ranging is 65mS, however you can shorten this by writing
to the range register before issuing a ranging command. Light sensor data at
location 1 will also have been updated after a ranging command.
ANN Mode
ANN mode (Artificial Neural Network) is
designed to provide the multi echo data in a way that is easier to input to a
neural network, at least I hope it is - I've not actually done it yet. ANN mode
provides a 32 byte buffer (locations 4 to 35 inclusive) where each byte
represents the 65536uS maximum flight time divided into 32 chunks of 2048uS each
- equivalent to about 352mm of range. If an echo is received within a bytes time
slot then it will be set to no-zero, otherwise it will be zero. So if an echo is
received from within the first 352mm, location 4 will be non-zero. If an object
is detected 3m away the location 12 will be non-zero (3000/352 = 8) (8+4=12).
Arranging the data like this should be better for a neural net than the other
formats. The input to your network should be 0 if the byte is zero and 1 if its
non-zero. I have a SOFM (Self Organizing Feature Map) in mind for the neural
net, but will hopefully be useful for any type.
Location 4 | Location 5 | Location 6 | Location 7 | Locations 8 - 35 |
0 - 352mm | 353 - 705mm | 706 - 1057mm | 1058 - 1410mm | and so on |
Locations 2,3 contain the range of the nearest object converted to inches, cm or uS and is the same as for Ranging Mode.
Checking for Completion of Ranging
You do not have to
use a timer on your own controller to wait for ranging to finish. You can take
advantage of the fact that the SRF08 will not respond to any I2C activity whilst
ranging. Therefore, if you try to read from the SRF08 (we use the software
revision number a location 0) then you will get 255 (0xFF) whilst ranging. This
is because the I2C data line (SDA) is pulled high if nothing is driving it. As
soon as the ranging is complete the SRF08 will again respond to the I2C bus, so
just keep reading the register until its not 255 (0xFF) anymore. You can then
read the sonar data. Your controller can take advantage of this to perform other
tasks while the SRF08 is ranging.
Changing the Range
The maximum range of the SRF08 is set
by an internal timer. By default, this is 65mS or the equivalent of 11 metres of
range. This is much further than the 6 metres the SRF08 is actually
capable of. It is possible to reduce the time the SRF08 listens for an echo, and
hence the range, by writing to the range register at location 2. The range can
be set in steps of about 43mm (0.043m or 1.68 inches) up to 11
metres.
The range is ((Range Register x 43mm) + 43mm) so setting the
Range Register to 0 (0x00) gives a maximum range of 43mm. Setting the Range
Register to 1 (0x01) gives a maximum range of 86mm. More usefully, 24 (0x18)
gives a range of 1 metre and 140 (0x8C) is 6 metres. Setting 255 (0xFF) gives
the original 11 metres (255 x 43 + 43 is 11008mm). There are two reasons you may
wish to reduce the range.
1. To get at the range information quicker
2. To
be able to fire the SRF08 at a faster rate.
If you only wish to get at the
range information a bit sooner and will continue to fire the SRF08 at 65ms of
slower, then all will be well. However if you wish to fire the SRF08 at a faster
rate than 65mS, you will definitely need to reduce the gain - see next
section.
The range is set to maximum every time the SRF08 is powered-up. If
you need a different range, change it once as part of your system initialization
code.
Analogue Gain
The analogue gain register sets the
Maximum gain of the analogue stages. To set the maximum gain, just write
one of these values to the gain register at location 1. During a ranging, the
analogue gain starts off at its minimum value of 94. This is increased at
approx. 70uS intervals up to the maximum gain setting, set by register
1. Maximum possible gain is reached after about 390mm of range. The purpose
of providing a limit to the maximum gain is to allow you to fire the sonar more
rapidly than 65mS. Since the ranging can be very short, a new ranging can be
initiated as soon as the previous range data has been read. A potential hazard
with this is that the second ranging may pick up a distant echo returning from
the previous "ping", give a false result of a close by object when there is
none. To reduce this possibility, the maximum gain can be reduced to limit the
modules sensitivity to the weaker distant echo, whilst still able to detect
close by objects. The maximum gain setting is stored only in the CPU's RAM and
is initialized to maximum on power-up, so if you only want do a ranging every
65mS, or longer, you can ignore the Range and Gain Registers.
Note - Effective in Ranging Mode only, in ANN mode,
gain is controlled automatically.
Gain Register | Maximum Analogue Gain | |
Decimal | Hex | |
0 | 0x00 | Set Maximum Analogue Gain to 94 |
1 | 0x01 | Set Maximum Analogue Gain to 97 |
2 | 0x02 | Set Maximum Analogue Gain to 100 |
3 | 0x03 | Set Maximum Analogue Gain to 103 |
4 | 0x04 | Set Maximum Analogue Gain to 107 |
5 | 0x05 | Set Maximum Analogue Gain to 110 |
6 | 0x06 | Set Maximum Analogue Gain to 114 |
7 | 0x07 | Set Maximum Analogue Gain to 118 |
8 | 0x08 | Set Maximum Analogue Gain to 123 |
9 | 0x09 | Set Maximum Analogue Gain to 128 |
10 | 0x0A | Set Maximum Analogue Gain to 133 |
11 | 0x0B | Set Maximum Analogue Gain to 139 |
12 | 0x0C | Set Maximum Analogue Gain to 145 |
13 | 0x0D | Set Maximum Analogue Gain to 152 |
14 | 0x0E | Set Maximum Analogue Gain to 159 |
15 | 0x0F | Set Maximum Analogue Gain to 168 |
16 | 0x10 | Set Maximum Analogue Gain to 177 |
17 | 0x11 | Set Maximum Analogue Gain to 187 |
18 | 0x12 | Set Maximum Analogue Gain to 199 |
19 | 0x13 | Set Maximum Analogue Gain to 212 |
20 | 0x14 | Set Maximum Analogue Gain to 227 |
21 | 0x15 | Set Maximum Analogue Gain to 245 |
22 | 0x16 | Set Maximum Analogue Gain to 265 |
23 | 0x17 | Set Maximum Analogue Gain to 288 |
24 | 0x18 | Set Maximum Analogue Gain to 317 |
25 | 0x18 | Set Maximum Analogue Gain to 352 |
26 | 0x20 | Set Maximum Analogue Gain to 395 |
27 | 0x21 | Set Maximum Analogue Gain to 450 |
28 | 0x22 | Set Maximum Analogue Gain to 524 |
29 | 0x23 | Set Maximum Analogue Gain to 626 |
30 | 0x24 | Set Maximum Analogue Gain to 777 |
31 | 0x25 | Set Maximum Analogue Gain to 1025 |
Note that the relationship between the Gain Register setting and
the actual gain is not a linear one. Also there is no magic formula to say "use
this gain setting with that range setting". It depends on the size, shape and
material of the object and what else is around in the room. Try playing with
different settings until you get the result you want. If you appear to get false
readings, it may be echo's from previous "pings", try going back to firing the
SRF08 every 65mS or longer (slower).
If you are in any doubt about the
Range and Gain Registers, remember they are automatically set by the SRF08 to
their default values when it is powered-up. You can ignore and forget about them
and the SRF08 will work fine, detecting objects up to 6 metres away every 65mS
or slower.
Light Sensor
The SRF08 has a light sensor on-board. A
reading of the light intensity is made by the SRF08 each time a ranging takes
place in either Ranging or ANN Modes ( The A/D conversion is actually done just
before the "ping" whilst the +/- 10v generator is stabilizing). The reading
increases as the brightness increases, so you will get a maximum value in bright
light and minimum value in darkness. It should get close to 2-3 in complete
darkness and up to about 248 (0xF8) in bright light. The light intensity can be
read from the Light Sensor Register at location 1 at the same time that
you are reading the range data.
LED
The red LED is used to flash out a code for the I2C
address on power-up (see below). It also gives a brief flash during the "ping"
whilst ranging.
Changing the I2C Bus Address
To change the I2C address
of the SRF08 you must have only one sonar on the bus. Write the 3 sequence
commands in the correct order followed by the address. Example; to change the
address of a sonar currently at 0xE0 (the default shipped address) to 0xF2,
write the following to address 0xE0; (0xA0, 0xAA, 0xA5, 0xF2 ). These commands
must be sent in the correct sequence to change the I2C address, additionally, No
other command may be issued in the middle of the sequence. The sequence must be
sent to the command register at location 0, which means 4 separate write
transactions on the I2C bus. When done, you should label the sonar with its
address, however if you do forget, just power it up without sending any
commands. The SRF08 will flash its address out on the LED. One long flash
followed by a number of shorter flashes indicating its address. The flashing is
terminated immediately on sending a command the SRF08.
Address | Long Flash | Short flashes | |
Decimal | Hex | ||
224 | E0 | 1 | 0 |
226 | E2 | 1 | 1 |
228 | E4 | 1 | 2 |
230 | E6 | 1 | 3 |
232 | E8 | 1 | 4 |
234 | EA | 1 | 5 |
236 | EC | 1 | 6 |
238 | EE | 1 | 7 |
240 | F0 | 1 | 8 |
242 | F2 | 1 | 9 |
244 | F4 | 1 | 10 |
246 | F6 | 1 | 11 |
248 | F8 | 1 | 12 |
250 | FA | 1 | 13 |
252 | FC | 1 | 14 |
254 | FE | 1 | 15 |
Take care not to set more than one sonar to the same address, there will be a bus collision and very unpredictable results.
Current Consumption
Average current consumption measured
on our prototype is around 12mA during ranging, and 3mA standby. The module will
automatically go to standby mode after a ranging, whilst waiting for a new
command on the I2C bus. The actual measured current profile is as follows;
Operation | Current | Duration |
Ranging command received - Power on | 275mA | 3uS |
+/- 10v generator Stabilization |
25mA |
600uS |
8 cycles of 40kHz "ping" | 40mA | 200uS |
Ranging | 11mA | 65mS max |
Standby | 3mA | indefinite |
The above values are for guidance only, they are not tested on production units.
You can have a look at the schematic and software
Your feedback/comments/criticisms and wish lists are very welcome,
as always.
Regards, Gerry.
gerry@robot-electronics.co.uk